Testing and Consulting Services

OUR EXPERTISE
Our Application Laboratory has more than 30 years experience in materials characterization and is able to offer you a huge range of analyses. We have a large pool of state of the art instrumentation ready to provide reliable thermal data.

On a daily basis we help to solve client’s problems from standardized testing on single or multiple samples, method development, complex data interpretation support.

OUR LOCATIONS
In addition to our application laboratory in France Caluire, we also have application laboratory in USA.

OUR ANALYSIS SPECTRUM
Our customers have access to Setaram Instrumentation thermal analysis, calorimetry, gas sorption analysis, data and expertise :

aaaa
  • For the understanding of the thermal behavior of their materials (drugs, bio, food, polymers, ceramics, metals, alloys,…) in order to investigate new materials, improve their quality or performances, build up safer, energy-saving, and environment-friendly processes
  • For a wiser use of their own thermal analysis instruments

Some applications of our thermal analysis, calorimetry, gas sorption analysers:

aaaa

A huge database is accessible in Setaram application library and show you what we have done and what we could do for you.

OUR MEASURING METHODS

DSC (Differential Scanning Calorimetry) – 120°C 1600°C
ASTM 537,E698,E793,E928,E968,E1269,E1356,E2009,E2069,E2070,E2160,E2253,D3895,
ISO 11357-1,11357-2,11357-3,11357-4,11357-5,11357-6,11409,11357-7,18373-1,18373-2

HP DSC (High Pressure Differential Scanning Calorimetry) -120°C 800°C 350 bars:
ASTM D5885, D6186

DTA (Differential Thermal Analysis) 20°C 2400°C: ASTME794,E967,E1782

CALORIMETRY -196°C 1600°C, vacuum to 1000 bars: ASTM C1702,C1458, STANAG 4582

MICRO CALORIMETRY -45°C 200°C

REACTION AND MIXING CALORIMETRY -196°C 300°C

TGA (Thermo Gravimetric Analyser)  -120°C 2400°C
ASTM E1131,E1582,E1641,E1868,E1877,E2008,E2040,E2402,E2403,E2550,E2551, D6370,D6375, ISO 11358-1, 11358-2

STA (Simultaneous Thermal Analyser): TGDTA -120°C 2400°C / TGDSC -120°C 1600°C

TMA (Thermo Mechanical Analyser)/Dilatometer ambient 2400°C: ASTM E228

TCi (Thermal conductivity) -50°C 200°C

CHARACTERIZATION OF EVOLVED GASES: MS, FTIR coupling to a TGA or STA

PCT (Pressure Composition Temperature) -260°C 500°C vacuum up to 200 bars

 

You are facing a problem in the above mentioned fields ? we may have a Thermal Analysis based solution !

For more detailed information / proof testing / quotation, do not hesitate to contact us : application@setaram.com +33 (0)4 72 10 25 80

100-Christine Christine Mayoux, head of the laboratory, says that the mission of the application team, is to be dedicated to customer support. This means answering customer questions on different applications fields, running tests to demonstrate the potential of our equipment or providing advices to optimize the measurement methods of users.