Batteries

Description

calorymetry-battery-picture

Batteries are essential power sources for every application from your new MP3 player, to the development of carbon neutral transportation. As demand for new and more powerful battery packs grows so do materials requirements. Setaram offers you a broad range of technologies for your laboratory, including traditional TGA and DSC as well as Gas Sorption techniques.

Experiments that can be obtained with some of our systems include:
–    self discharge test
–    life cycle test
–    “abuse testing”
–    thermal stability
–    oxide characterization
–    membrane permeability

Some References
Université Picardie – France

 

Associated products

Silmultaneous Thermal Analysis Platform (STA) with Evolved Gas Analysis (EGA) from ambient to 1600°C

THEMYS 2017 3-4- OK

THEMYS TGA/STA-EGA (Evolved Gas Analysis)

  The THEMYS is the NEW benchmark for modular thermogravimetric analysis. The THEMYS is available in various platforms: Standard Thermogravimetric Analysis (TGA), high pressure TGA, Simultaneous Thermal Analysis (STA) TG/DSC, Differential Thermal Analysis / Differential Scanning Calorimetry (DTA/DSC), and Evolved Gas...

Read more »

THEMYS 2017 3-4- OK

THEMYS TGA (Thermogravimetric Analysis)

Thermogravimetric Analyzer up to 1750°C The THEMYS is the NEW benchmark for modular thermogravimetric analysis. The THEMYS is available in various platforms: Standard Thermogravimetric Analysis (TGA), high pressure TGA, Simultaneous Thermal Analysis (STA) TG/DSC, Differential Thermal Analysis / Differential Scanning Calorimetry (DTA/DSC), and Evolved Gas Analysis (EGA). The design of the THEMYS is to provide...

Read more »

THEMYS 2017 3-4- OK

THEMYS STA (Simultaneous Thermal Analysis)

Simultaneous Thermal Analyzer (TGA/DSC – DTA) up to 1750°C The THEMYS is the NEW benchmark for modular thermogravimetric analysis. The THEMYS is available in various platforms: Standard Thermogravimetric Analysis (TGA), high pressure TGA, Simultaneous Thermal Analysis (STA) TG/DSC, Differential Thermal Analysis / Differential Scanning Calorimetry (DTA/DSC), and Evolved Gas Analysis (EGA). The design of the...

Read more »

Very High Sensitivity Isothermal Calorimeter (ambient to 200°C)

MS80-Calorimeter-Setaram2

MS80

The MS80 calorimeter has the greatest sensitivity in the Calvet 3D calorimeter range.It is It is mostly used in isotherm mode, between ambient temperature and + 200°C,and is intended for measurements of very low thermal effects: self-discharge of batteries, self-decomposition of powders, heat generation of plants and...

Read more »

Documentation

Application notes
Articles See articles